Run # 1223 Tape: EXABYTE Shift: SHIFT 3 Date: 960923 Time: 07:02:27 # of events: 998 Start block: 0 Last block:___________ DAQ conf.: VT1: OFF VT2: OFF MTL: OFF MTR: OFF TOF: OFF TOFG: ON
Beam: PROTON    Energy:  158 GeV/n   Target:  MULTI      Thickness:      0 mg

Trigger: B                  S3/S4/S5: -14 mV                  VETO:      0 mV

Magnet conf.:          Magnet#1:     0 A/  0.0 T    Magnet#2:     0 A/  0.0 T 
Scaler readings (10 spills): S1: _________ V0: _________ B(gated): ________ Triggers: _________ Trig./B(gated): ________

beams for veto study - STOPPED NORMALLY
Atmospheric pressure:     0.000 mbar    T0:   1.470 us

VT1:
gas: NE:91%/CO2:9%             Temp.:  0.0 C     drift velocity:  0.00000
drift: 0.000   kV        sense wires: 1110/1060 V   gating grid:-115/+-45 V

VT2:
gas: NE:91%/CO2:9%             Temp.:  0.0 C     drift velocity:  0.00000
drift: 0.000   kV        sense wires: 970       V   gating grid:-115/+-45 V

MTL:
gas: AR:91%/CH4:4.5%/CO2:4.5%  Temp.:  0.0 C     drift velocity:  0.00000
drift: 0.000   kV        sense wires: 1030/1100 V   gating grid:-110/+-50 V

MTR:
gas: AR:91%/CH4:4.5%/CO2:4.5%  Temp.:  0.0 C     drift velocity:  0.00000
drift: 0.000   kV        sense wires: 1030/1100 V   gating grid:-110/+-50 V