Run # 1309 Tape: EXABYTE Shift: SHIFT 4/MG Date: 961019 Time: 19:18:30 # of events: 3133 Start block: 0 Last block:___________ DAQ conf.: VT1: OFF VT2: OFF MTL: OFF MTR: OFF TOF: OFF TOFG: ON
Beam: PB        Energy:  157 GeV/n   Target:   PB        Thickness:      0 mg

Trigger: S1,V0_BAR          S3/S4/S5: 80 mV                   VETO:      0 mV

Magnet conf.:          Magnet#1:     0 A/  0.0 T    Magnet#2:     0 A/  0.0 T 
Scaler readings (10 spills): S1: _________ V0: _________ B(gated): ________ Triggers: _________ Trig./B(gated): ________

Veto calorimeter fragments only, BPD4 HV 1200 V, BPD5 HV 1400 V, BPD4 position +5 mm in x. - STOPPED NORMALLY
Atmospheric pressure:   972.000 mbar    T0:   1.470 us

VT1:
gas: NE:91%/CO2:9%             Temp.: 20.2 C     drift velocity:  1.40156
drift: 12.990  kV        sense wires: 1010/1010 V   gating grid:-115/+-45 V

VT2:
gas: NE:91%/CO2:9%             Temp.: 19.7 C     drift velocity:  1.40318
drift: 12.933  kV        sense wires: 970       V   gating grid:-115/+-45 V

MTL:
gas: AR:91%/CH4:4.5%/CO2:4.5%  Temp.: 20.1 C     drift velocity:  2.31296
drift: 18.998  kV        sense wires: 970/1040  V   gating grid:-110/+-50 V

MTR:
gas: AR:91%/CH4:4.5%/CO2:4.5%  Temp.: 21.3 C     drift velocity:  2.32182
drift: 18.979  kV        sense wires: 1030/1100 V   gating grid:-110/+-50 V