Run # 1125 Tape: YA0154 Shift: SP Date: 960909 Time: 16:48:02 # of events: 125 Start block: 251221 Last block:___________ DAQ conf.: VT1: ON VT2: ON MTL: ON MTR: ON TOF: OFF TOFG: OFF
Beam: PROTONS   Energy:  158 GeV/n   Target:   LH2       Thickness:     14 mg

Trigger: B*S4BAR*C1         S3/S4/S5: -6 mV                   VETO:      0 mV

Magnet conf.:          Magnet#1:     0 A/  0.0 T    Magnet#2:     0 A/  0.0 T 
Scaler readings (10 spills): S1: _________ V0: _________ B(gated): ________ Triggers: _________ Trig./B(gated): ________

pulser calib run - STOPPED BY DAQ FAILURE
Atmospheric pressure:   963.000 mbar    T0:   1.470 us

VT1:
gas: NE:91%/CO2:9%             Temp.: 21.1 C     drift velocity:  1.39068
drift: 12.990  kV        sense wires: 1110/1060 V   gating grid:-115/+-45 V

VT2:
gas: NE:91%/CO2:9%             Temp.: 19.7 C     drift velocity:  1.39276
drift: 12.933  kV        sense wires: 970       V   gating grid:-115/+-45 V

MTL:
gas: AR:91%/CH4:4.5%/CO2:4.5%  Temp.: 20.1 C     drift velocity:  2.32909
drift: 18.996  kV        sense wires: 1030/1100 V   gating grid:-110/+-50 V

MTR:
gas: AR:91%/CH4:4.5%/CO2:4.5%  Temp.: 21.3 C     drift velocity:  2.32838
drift: 18.996  kV        sense wires: 1030/1100 V   gating grid:-110/+-50 V