Run # 1748 Tape: YA0315 Shift: SHIFT 1 Date: 971012 Time: 20:55:15
# of events: 53520 Start block: 0 Last block:___________
DAQ conf.: VT1: ON VT2: ON MTL: ON MTR: ON TOF: ON TOFG: ON
Beam: P Energy: 158 GeV/n Target:PB Thickness: 0 mg
Trigger: BEAM*S4BAR S3/S4/S5: 8 mV VETO: 0 mV
Magnet conf.: Magnet#1: 0 A/ 0.0 T Magnet#2: 0 A/ 0.0 T
Scaler readings (10 spills): S1: _________ V0: _________ B(gated): ________
Triggers: _________ Trig./B(gated): ________
min. bias target in CD HV 1300. TPC Pedestals taken and written to tape robot. - STOPPED BY END OF TAPE
Atmospheric pressure: 960.000 mbar T0: 1.470 us
VT1:
gas: NE:90%/CO2:10% Temp.: 20.2 C drift velocity: 1.38806
drift: 12.983 kV sense wires: 1110/108 V gating grid:-115/+-4 V
VT2:
gas: NE:90%/CO2:10% Temp.: 19.8 C drift velocity: 1.39125
drift: 12.922 kV sense wires: 990 V gating grid:-115/+-4 V
MTL:
gas: AR:90%/CH4:5%/CO2:5% Temp.: 20.1 C drift velocity: 2.29493
drift: 18.995 kV sense wires: 1030/110 V gating grid:-110/+-7 V
MTR:
gas: AR:90%/CH4:5%/CO2:5% Temp.: 21.3 C drift velocity: 2.30768
drift: 18.970 kV sense wires: 1030/110 V gating grid:-110/+-7 V