Run # 1749 Tape: YA0316 Shift: SHIFT 3 Date: 971013 Time: 07:41:17 # of events: 1074 Start block: 7000 Last block:___________ DAQ conf.: VT1: ON VT2: ON MTL: ON MTR: ON TOF: ON TOFG: ON
Beam: P         Energy:  158 GeV/n   Target:PB           Thickness:      0 mg

Trigger: BEAM*S4BAR         S3/S4/S5: 8 mV                    VETO:      0 mV

Magnet conf.:          Magnet#1:     0 A/  0.0 T    Magnet#2:     0 A/  0.0 T 
Scaler readings (10 spills): S1: _________ V0: _________ B(gated): ________ Triggers: _________ Trig./B(gated): ________

min. bias target in CD HV 1300. TPC Pedestals taken and written to tape robot. Marburg TOF taken out due to the initializtion problems. - STOPPED NORMALLY
Atmospheric pressure:   961.000 mbar    T0:   1.470 us

VT1:
gas: NE:90%/CO2:10%            Temp.: 20.2 C     drift velocity:  1.38848
drift: 12.983  kV        sense wires: 1110/108  V   gating grid:-115/+-4  V

VT2:
gas: NE:90%/CO2:10%            Temp.: 19.8 C     drift velocity:  1.39113
drift: 12.922  kV        sense wires: 990       V   gating grid:-115/+-4  V

MTL:
gas: AR:90%/CH4:5%/CO2:5%      Temp.: 20.1 C     drift velocity:  2.29558
drift: 18.995  kV        sense wires: 1030/110  V   gating grid:-110/+-7  V

MTR:
gas: AR:90%/CH4:5%/CO2:5%      Temp.: 21.3 C     drift velocity:  2.30821
drift: 18.971  kV        sense wires: 1030/110  V   gating grid:-110/+-7  V