Run # 1992 Tape: YA0361 Shift: BET.,RENF.,S Date: 980811 Time: 21:31:14
# of events: 13628 Start block: 7000 Last block:___________
DAQ conf.: VT1: ON VT2: OFF MTL: ON MTR: ON TOF: OFF TOFG: OFF
Beam: MUONS Energy: 158 GeV/n Target:NONE Thickness: 0 mg
Trigger: MUON S3/S4/S5: 8 mV VETO: 0 mV
Magnet conf.: Magnet#1: 0 A/ 0.0 T Magnet#2: 0 A/ 0.0 T
Scaler readings (10 spills): S1: _________ V0: _________ B(gated): ________
Triggers: _________ Trig./B(gated): ________
u trigger, std conf: 512 t. b., fltr=2, thrsh.=5, VT2 off - STOPPED BY DAQ FAILURE
Atmospheric pressure: 0.000 mbar T0: 1.470 us
VT1:
gas: AR:90%/CO2:10% Temp.: 0.0 C drift velocity: 0.00000
drift: 0.000 kV sense wires: 1200/117 V gating grid:-115/+-4 V
VT2:
gas: AR:90%/CO2:10% Temp.: 0.0 C drift velocity: 0.00000
drift: 0.000 kV sense wires: 1050 V gating grid:-115/+-4 V
MTL:
gas: AR:90%/CH4:5%/CO2:5% Temp.: 0.0 C drift velocity: 0.00000
drift: 0.000 kV sense wires: 1030/110 V gating grid:-110/+-7 V
MTR:
gas: AR:90%/CH4:5%/CO2:5% Temp.: 0.0 C drift velocity: 0.00000
drift: 0.000 kV sense wires: 1030/110 V gating grid:-110/+-7 V